| Electrical
Parameter | Environment &
Safety Specification |
| Input
Voltage Range | 90-264Vac | Operating Temperature | 0℃~45℃ |
| Input
Frequency | 50/60Hz | Storage Temperature | -20℃~ 85℃ |
| Inrush
Current | <50A | Storage Humidity | 5~95% |
| Hold up
Time | >10mS | Cooling Mode | Natural Cooling |
| Turn on
Delay(s) | <3 | MTBF | ≧100,000Hrs @full load |
| Rated
Output Voltage | Double USB1: 5.2V 4.8A
Max,Double USB2: 5.2A 4.8A Max, Total 25W | Surge Voltage | ±1KV |
| Max.
Output Current | 3.0A Max. | Insulation Voltage | 3KVac @ Primary v.s. Secondary |
| Output
Voltage Tolerance | <±5% | Insulation Resistance | >10Mohm @ Primary v.s.
Secondary @ 500Vdc |
| Ripple
and Noise (Vpp) | <100mV | Leakage Current | <250uA |
| Efficiency
(%) | >84.5% (Energy level VI) | Safety Mark & Standards
Complicance | UL, FCC, IEC60950, UL60950 |
| Static
Loss | <0.075W | EMC & EMI Standards
Complicance | FCC Part 15 Class B; EN55032 |
| Protection
Function | OVP, OCP, SCP,OTP | Dimension (L*W*H) mm | 42*39*25mm |